OI 0505931
Electronics International Inc.
63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • www.Buy-EI.com
5/5/93
Rev. H: 2/17/05
Operating Instructions
(FP-5 and FP-5L)
Fuel Flow / Pressure
You must read this manual before installing or operating the instrument. This
manual contains warranty and other information that may affect your decision
to install this product and/or the safety of your aircraft.
®
Vista de pagina 0
1 2 3 4 5 6 ... 26 27

Indice de contenidos

Pagina 1 - Fuel Flow / Pressure

OI 0505931Electronics International Inc.63296 Powell Butte Hwy • Bend, OR 97701 • (541) 318-6060 • www.Buy-EI.com5/5/93Rev. H: 2/17/05Operating

Pagina 2 - Important Notice

82. “REM” (Remaining) Display Mode:In the “REM” (Fuel Remaining) Display Mode, the FP-5(L) willdisplay the fuel in the aircraft tanks as follows:A. W

Pagina 3 - Contents

9Example: * You start your flight with full tank(s) and go fly. * You land and pull up to the pumps, taking on 30.0 gallons of fuel. * The FP

Pagina 4

c) To Exit - To exit the "Auto Calibration Mode", momentarily push both “PRG” buttons at thesame time. The new K Factor will be displayed f

Pagina 5 - Operating Instructions

11than when it was tested at the factory. To insure accuracy, which is essential, the FP-5(L) provides a pilot-programmable K Factor to correct for t

Pagina 6 - Upper Bar Showing

126. “T. to E. / MPG” (Time to Empty / Miles per Gallon) Display Mode:"Time to Empty" is calculated by dividing "Fuel Remaining"

Pagina 7

13Also, the "AUX" channel can be set up to display a decimal point (for pressure, volts, etc. measurements) anddisplay "00" for re

Pagina 8

14show " " (note the tick mark in the upper left corner of the display). If the baud rate is correct but theground speed and distance to

Pagina 9

1. Setting the display for “Gal”, "br Gal", “Lbs” or "Ltr" in the "Flow" Display Mode:In the "FLOW" Display M

Pagina 10

this alarm is 30 minutes’ worth of fuel (at cruise) for a VFR pilot or 45 minutes for an IFR pilot. In the“REM” display mode a bar in the lower left

Pagina 11 - Blinking Digit

Reoccurring Fuel Used Alarm - The Reoccurring Fuel Used Alarm may be programmed to blink the LowFuel Warning LED each time the fuel used reaches the p

Pagina 12

FP-5 and FP-5LImportant Notice********** Must Read **********If you think it is not important to read this manual, you're wrong! This manualcont

Pagina 13

set to the highest acceptable level for the function measured. In the “AUX” Display Mode a bar in the upperleft corner of the display will be shown w

Pagina 14 - 1:22 n 9.3 10.7

Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Settings:Power-Up Programmable Sett

Pagina 15

3. The ability of the line attendant to fill the tank to the same mark. Also, the shape of the tank and thedihedral of the wings can aggravate the s

Pagina 16 - Pilot-Programmable Settings:

B. Program the Fuel Flow Setting in the FP-5(L) using the following formula: FF@75% rich x 75Fuel Flow Setting = --------

Pagina 17

B. To display a decimal point in the AUX Display Mode, set the AUX Channel Control Setting #2to "000." The decimal point would be used when

Pagina 18 - Blinking Digit (0)

11. Scan Rate:The Scan Rate (the time the FP-5(L) takes to switch between display modes) canbe set from 0 to 9 seconds. A "0" setting disa

Pagina 19

24Specifications and Operating FeaturesModel:FP-5 and FP-5L (Fuel Flow/Pressure Instrument)Case Dimensions:2.5" x 2.5" x 3.65" depth, 2

Pagina 20 - Blinking Digits (15)

Max Displayed Range (Instrument Only):Fuel Flow: 199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.Fuel Remaining: 999 Gals. or 811 br Gal

Pagina 21

ContentsWWWWWarranty ...arranty ...

Pagina 22

2WWWWWarranty / Agreementarranty / Agreementarranty / Agreementarranty / Agreementarranty / AgreementElectronics International Inc. (E.I. inc.) warran

Pagina 23 - Blinking Digits

FP-5 and FP-5LOperating InstructionsSystem Description:System Description:System Description:System Description:System Description:The FP-5 and FP-5L

Pagina 24

4In addition to these seven display modes both units have the following pilot programmable settings (used toset up the display and alarms): Display in

Pagina 25

B. Second Low Fuel Alarm: This alarm should be set as a warning (example: 5 gallons). When theAlarm Limit is violated the red Low Fuel Warning LED w

Pagina 26

6Display Modes and Operating Features:Display Modes and Operating Features:Display Modes and Operating Features:Display Modes and Operating Features:D

Pagina 27

7When displaying Fuel Flow, the FP-5(L) will operate as follows:A. When set to display in Gallons the display will read in .1 Gal/Hr increments up to