0906941Single and Multi-ChannelEGT, CHT, Carb Temp and OAT InstrumentsOperating and Installation InstructionsOII 09069419/6/94Electronics Internationa
Operating Information7CHT'sIt is not necessary to continually monitor the EGTs in order to detect a problem. Most problems worsenover a period
8Carburetor TemperatureOperating InformationContinuous change in the CHT can also be a sign of trouble. Because of the large thermal mass of theengin
9The second valuable feature is the instrument's ability to detect small temperature changes (1F). This givesthe pilot rate and trend informati
Installation Instructions102. CHT Probe InstallationH. If this instrument is to replace an existing unit in the aircraft, it is the installer's
NOTE: A Carb Temp Probe should be connected to the precision channel on a CA-1, A-1 or EAC-1 unit. Athree to four degree F error can occur in some i
Installation Instructions126. Route the Extension CablesD) Strip each wire and double the wires over. These wires must be doubled over.E) Place a ma
7. Hook-Up Connecting Wires:Connect the red wire supplied in the kit to the 12 or 24 volt bus via a 1 amp fuse or circuit breaker (see theWiring Diag
14TROUBLESHOOTING SUGGESTIONSBecause high reliability is designed into Electronics Internationals equipment, there is no reason to put up withpoor o
A. Poor Connections: When plugging the probe into the extension cable it is possible to get the tab onthe male connector to wedge between the red ny
16SPECIFICATIONS and OPERATING FEATURESS09089419/8/94Models: (Temperature Monitoring Instruments) E-1, C-1, A-1, CA-1, EAC-1, EAE-1, EC-1, EC-2, E-2
Important Installation Information07209211. Leave slack in the cable to allowfor engine movement and vibration.All steps must be read befor
"Brown" PairRedBlackWht/VioletWht/GrayWht/OrgInstrumentBack PanelE-1 or C-1 Additional ConnectionsA-1 or CA-1 Additional ConnectionsEC-1 Add
18Remote Switch Wiring DiagramTo Instrument EGT or CHT Channel.(For a twin unit, to Instrument Left or Right Channel)To Cyl. #1.To Cyl. #2.To Cyl. #3.
To Instrument EGT or CHT Channel.To Cyl. #1.To Cyl. #2.To Cyl. #3.To Cyl. #4.To Cyl. #5.To Cyl. #6.To Cyl #7.To Cyl #8.To Cyl #9 (RS-12-1 only).To Cyl
Important Notice***** MUST READ *****If you think it is not important to read this manual, you're wrong! This manualcontains important installat
ContentsWarranty --------------------------------------------------------------------------- 2Operating Instructions: ------------------------
2Warranty / AgreementElectronics International Inc. warrants this instrument and system components to be free from defects inmaterials and workmanship
OPERATING INSTRUCTIONSFeatures1. Instruments:The Electronics International line of single and multi-channel instruments offer the following features:
EGT'sOperating Instructions42. Remote Switches:A remote switch may be connected to any channel on any Electronics InternationalInstrument. This
5EGT'sOperating Informationyou approach peak, the exhaust gas temperature will rise much slower until it starts to decrease. Whenthis happens yo
Operating Information6EGT'sengines tend to operate smoother at 25F on the rich side of peak EGT. Fuel-injected engines will provide amore preci