13. Place the Selector Switch into the right position. The FL-2 will display the last programmed Sensor
Counts for this cal point.
Tap the Enter Button on the back of the FL-2, the display will start
blinking and the Sensor Counts for the current fuel level in the tank
will be displayed. Wait for the display to stabilize and tap the Enter
Button to lock the current sensor counts into the display, and stop the
blinking.
14. Record the Sensor Counts for this cal point on the calibration chart at
the back of this section.
15. Perform steps 10 trough 14 for each cal point. Once you have calibrated the full fuel level, the FL-2 will
evaluate the calibration data for any errors. The error codes are listed on the following table.
10561056
10561056
1056
sedoCrorrE
knaTtfeLknaTthgiRstnemmoC
1L1r
si)ytpmE(1tnioPlaCrofstnuoCrosneSehT
.)2703>(hgihoot
2L2r
9llA.gnissimsitniopnoitarbilaCleuFlluFehT
.slevelleuflaitraproferastnioPlaC
3L3r.snollag4nahtsselsileveLleuFlluFehT
4L4r
siytpmednallufneewtebstnuoCrosneSehT
.stnuoc002nahtssel
5L5r
tnioPlaCevisseccushcaeroflevelleufehT
sieromroenO.tsalehtnahtrehgihebtsum
.ton
1100301
Note: On every power-up, the FL-2 checks the left tank calibration data for errors and if there are no
errors, it checks the right tank calibration data for errors. If an error is found, the FL-2 displays the first
error it finds and locks the FL-2 into a nonoperating mode with the first error code found shown in the
digital display.